RJ-45 interfaces
(24) 10/100/1000 RJ-45 ports
SFP interfaces
(2) 100/1000 SFP slots
PoE capacity
370 Watts
Power input
100-240VAC
Thermal range
0°C to +50°C
Included cord
North America power cord

Who it's for

Is the SM24TAT2SA-NA the right part?

This North America-cord model fits a commercial wiring-closet design that needs 24 Gigabit PoE+ connections with a shared 370 W allocation. Two SFP positions support the uplink plan without consuming copper endpoint connections. The combination of DMS, traffic controls and Percepxion integration gives the team installing cameras or wireless access points tools for documenting the deployment and supporting it after handover.

Ordering

Which SKU do I need?

Part numberWhat’s differentPrice
SM24TAT2SA-NAThis pageSMTATSA PoE+ Switch With North America Cord$858.60
SM8TAT2SA-NANorth America cord with 8 copper ports and a 130 W PoE allocation.$435.02
SM8TAT2SA-LA8 copper ports and 130 W PoE; its ordering row specifies a South America cord.$435.02
SM8TAT2SA-EU8 copper ports and 130 W PoE with a European cord.$435.02
SM8TAT2SA-UK8 copper ports and 130 W PoE with a United Kingdom cord.$435.02
SM8TAT2SA-SA8 copper ports and 130 W PoE with a South America cord.$435.02
SM8TAT2SA-JP8 copper ports and 130 W PoE with a Japan cord.$435.02
SM8TAT2SA-OZ8 copper ports and 130 W PoE with an Australia cord.$435.02
SM8TAT2SA-BR8 copper ports and 130 W PoE with a Brazil cord.$435.02
SM16TAT2SA-NANorth America cord with 16 copper ports and a 250 W PoE allocation.$744.12
SM16TAT2SA-LA16 copper ports and 250 W PoE with a Latin America cord.$744.12
SM16TAT2SA-EU16 copper ports and 250 W PoE with a European cord.$744.12
SM16TAT2SA-UK16 copper ports and 250 W PoE with a United Kingdom cord.$744.12
SM16TAT2SA-SA16 copper ports and 250 W PoE with a South America cord.$744.12
SM16TAT2SA-JP16 copper ports and 250 W PoE with a Japan cord.$744.12
SM16TAT2SA-OZ16 copper ports and 250 W PoE with an Australia cord.$744.12
SM16TAT2SA-BR16 copper ports and 250 W PoE with a Brazil cord.$744.12
SM24TAT2SA-LAEquivalent 24-port selection with a Latin America cord.$858.60
SM24TAT2SA-EUEquivalent 24-port selection with a European cord.$858.60
SM24TAT2SA-UKEquivalent 24-port selection with a United Kingdom cord.$858.60
SM24TAT2SA-SAEquivalent 24-port selection; its ordering row identifies a South America cord.$858.60
SM24TAT2SA-JPEquivalent 24-port selection with a Japan cord.$858.60
SM24TAT2SA-OZEquivalent 24-port selection with an Australia cord.$858.60
SM24TAT2SA-BREquivalent 24-port selection with a Brazil cord.$858.60
LantronixInstallerV03.01bMilestone XProtect VMS plug-in entry, not a port-count or cord variant.Quote

Compare every SM24TAT2SA part number

Define the Closet Connection Plan

SM24TAT2SA-NA supplies twenty-four RJ-45 connections for 10/100/1000Base-T endpoints and two separate SFP positions for 100/1000Base-X uplinks. The platform supports fiber or copper uplink designs, a 52 Gbps backplane and an 8k MAC table.

Use the Layer 2 feature set to organize access traffic: VLANs provide segmentation, LACP and static trunks provide aggregation, and spanning-tree options include MSTP, RSTP and STP. IGMP and MLD snooping address multicast handling.

Keep Endpoint Power and AC Demand Separate

The 370 W figure describes the available PoE allocation. The published output configurations specify twelve simultaneous 30 W ports or twenty-four simultaneous 15.4 W ports. PoE configuration, Auto Power Reset and Always on PoE are supported alongside IEEE 802.3af and 802.3at.

For facility planning, the full-load electrical consumption is 438 W including PoE. The internal, fixed supply accepts 100–240 VAC, and surge protection is listed at 6KV. The NA package provides a North America power cord.

Document the Rack and Operational Handover

The fanless 1U enclosure ships with brackets for a 19-inch rack. Its operating limits are 0°C to +50°C and 10% to 90% non-condensing humidity. Use the installation guide to support the physical deployment plan.

DMS offers visual device layouts, traffic inspection and diagnostic functions. It supports establishing a deployment record, discovering attached powered devices and configuring them remotely. Percepxion adds cloud platform access, while the web user guide documents browser administration for the support team.

Choose this part if…

  • Choose this part if the rack specification requires a North America power cord.
  • Pick this SKU when 24 copper endpoint connections and two separate SFP positions are needed.
  • Choose this part if the PoE load plan fits within 370 W.
  • Pick this SKU when the site provides 100–240 VAC and stays within 0°C to +50°C.
  • Choose this part if DMS diagnostics and cloud integration belong in the support plan.

Technical data

SM24TAT2SA-NA specifications

Ethernet and Switching

Interface total26 total ports
RJ-45 connections(24) 10/100/1000 RJ-45 ports
Copper physical layer10/100/1000Base-T
SFP positions(2) 100/1000 SFP slots
SFP physical layer100/1000Base-X
Uplink mediafiber or copper uplinks
Switch layerLayer 2
Backplane52 Gbps
Forwarding designStore-and-forward switching architecture
MAC table8k MAC address table
ProtocolCSMA/CD
Jumbo-frame maximum9K bytes
IP stackIPv4/IPv6 dual protocol stack

Traffic Controls

VLANPort Based VLAN, IEEE 802.1Q tag-based, up to 4k VLAN entries, QinQ, MAC based VLAN, Private VLAN
TrunkingIEEE 802.3ad; link aggregation control protocol (LACP); static trunk
IGMPIGMP Snooping V1/V2
MLDMLD Snooping V1/V2
Multicast VLAN registrationMVR
Spanning-tree optionsIEEE 802.1s MSTP; IEEE 802.1w RSTP; IEEE 802.1D STP
QoS queue resources8 hardware queues
SchedulingStrict priority and WRR
Traffic rate controlsIngress policer, Egress shaping and per port rate limiting

Security and Addressing

AuthenticationRADIUS, TACACS+
ACL supportL2/L3/L4 ACLs Support MAC ACL, IP standard/extended ACL
Source and port controlsIP Source Guard, Port Security
IPv6 administrationIPv6 Access Management
DHCP functionsDHCP Server; DHCP Snooping; DHCP Relay

Management

Web administrationWeb Management
SNMPSNMP V1/V2c/V3
Command accessTelnet, CLI
Device managerDMS web manager
Cloud integrationPercepxion IoT Edge Solutions Platform
Cloud functionsdevice life cycle management; enterprise application integration; data analytics
DMS accessPercepxion or the local web manager
Display modesFloor view; Map view; Topology view
Floor layout creationfloor map creator
Traffic visibilityTraffic Monitoring
Diagnostic functionsNetwork diagnostic; protection mechanism; performance and link management
Discovery of attached devicesautomatically discover
Remote device setupremotely configure
Deployment recordsbaseline deployment
Firmware transferTFTP and HTTP
Link discoveryLLDP (Link Layer Discovery Protocol)
Event loggingSyslog

Power and PoE

AC input100-240VAC
Power supplyInternal / fixed PSU
PoE allocation370 Watts
Per-port output across 12 active ports30 Watts
Per-port output across 24 active ports15.4 Watts
PoE complianceIEEE 802.3at PoE+; IEEE 802.3af PoE
Power managementAlways on PoE; Auto Power Reset (APR); PoE configuration
Full-load power draw438 Watts (full load with PoE)
Surge protection6KV
Energy-efficient EthernetIEEE 802.3az

Installation and Environment

Dimensions17.4” [442 mm] x 8.3” [211 mm] x 1.73” [44 mm]
Weight6.6 lbs. [3.0 kg]
Rack height1U
MountingRack mount
Cooling designFan-less Design
Operating temperature0°C to +50°C
Humidity range10% to 90% (non-condensing)

Compliance

SafetyIEC62368/EN62368, UL listed
CertificationsFCC Class A, CE, NOM
StandardsIEEE 802.3; IEEE 802.3u; IEEE 802.3z; IEEE 802.3ab; IEEE 802.3x; IEEE 802.3ad; IEEE 802.1D; IEEE 802.1w; IEEE 802.1s; IEEE 802.1Q; IEEE 802.1p; IEEE 802.1ad; IEEE 802.1AB; IEEE 802.3af; IEEE 802.3at; IEEE 802.3az

Ordering

Supplied brackets19” rack mount brackets
Supplied cordNorth America power cord
RegionNorth America
Warranty5 Years
UPC648177040780

Questions

SM24TAT2SA-NA FAQ

How does this compare with the 16-port North America model?

SM16TAT2SA-NA supplies 16 copper connections, a 250 W PoE allocation and a 36 Gbps backplane. This 24-port model raises those figures to 24, 370 W and 52 Gbps; both have two SFP positions.

Which spanning-tree protocols are available?

The series supports MSTP under IEEE 802.1s, RSTP under IEEE 802.1w and STP under IEEE 802.1D.

What is the full-load AC consumption?

The specification lists 438 W including PoE, with a 100–240 VAC input range.

Does the chassis require fans?

The series is specified as fanless. It uses a 1U rack enclosure and operates from 0°C to +50°C.

Which documents support an operational handover?

The installation guide, web user guide, DMS feature overview and Auto Power Reset overview cover the main deployment and support functions described for the series.

Support & warranty plans

Lantronix LEVEL coverage for this part. Add a plan at the time of purchase to lock in the term from the ship date.